Mon–Sat 9:00–19:00 (UTC+8)

Custom Artificial Restaurant Feature Ficus for Hotel Atriums & Lobbies

Application: Hotel Atriums & Lobbies · Custom heights 3–6 m

We build custom artificial ficus trees for hotel atriums and lobbies — 3–6 m specimens, NFPA 701 fire-retardant treatment available as an option, engineered per project. Atrium trees must read from three floors up, pass a fire inspection, and still look right in a guest's photo years later. We engineer specimens from 2 to 12 m that do all three, delivered and installed worldwide.

  • Canopy height set to clear seated guests
  • Wipe-clean matte PE foliage
  • No structural work required for installation
Technical Specifications

Restaurant Feature Ficus Build Spec

Unit Size3–6 m, canopy 2–4 m
Height Range2–8 m (customizable to your photos or drawings)
TrunkSculpted fiberglass trunk with multi-stem branching.
FoliagePE and PU materials; optional UV-resistant finish for outdoor use.
BaseSteel plate base — set in concrete or installed in a planter.
Fire RetardancyOptional NFPA 701 / BS 5867.
MaintenanceNo routine maintenance — no watering, feeding or leaf cleanup.
Lead TimeStandard builds 7–10 days; custom builds 15–20 days.
Sizing & Compliance for Hotel Atriums & Lobbies

What This Venue Needs

Sizing

Specimens run 2–12 m; above the height that fits a container upright they are engineered knock-down and assembled in place, with rigging notes for your contractor.

Compliance & Anchoring

NFPA 701 fire-retardant foliage is available as an option, with EN 13501 B-s1,d0 available for EU hotels. Base-plate loading and anchoring details ship with every large build.

Project Specification

Restaurant Feature Ficus specified for Hotel Atriums & Lobbies

Restaurant Feature Ficus (SKU VW-FIC-600) is quoted at 3–6 m for hotel atriums and lobbies, against the 2–12 m height band this venue is engineered for. The review pack is assembled for a hotel operator, not a single buyer.

Buying parameters for this venue

Reference SKUVW-FIC-600
Species height range3–6 m
Venue height band2–12 m
Base & fixingKnock-down assembly · Rigging notes supplied
DocumentationFor VW-FIC-600: NFPA 701 fire-retardant foliage is available as an option, with EN 13501 B-s1,d0 available for EU hotels. Base-plate loading and anchoring details ship with every large build.
Palm canopy on steel base plates, factory showroom
Palm canopy on steel base plates, factory showroom

Installation, materials & documentation

Installation is scheduled around guest access: the crown arrives in numbered rings and the trunk as engineered knock-down parts that bolt to the base plate inside a closed work zone, and the area reopens only after the anchoring check is signed off.

The submittal pack carries the foliage fire report, base-plate loading and the sprinkler-clearance drawing. Housekeeping receives a branch-ring map so reachable sections can be lifted off for cleaning without closing the lobby.

Buyer Questions

Ordering & Specification FAQs

What buyers ask when specifying ficus trees for hotel atriums and lobbies — MOQ, lead time and this venue's requirements.

MOQ is project-based rather than per-SKU. A restaurant ficus at 3–6 m with a 2–4 m canopy can be quoted on its own; the multi-stem branching and the canopy height above seated guests are specified per tree, and a single replacement tree is quoted exactly like a full dining-room scheme.

7–10 days for standard builds, and 15–20 days for custom builds. Lead time starts from approved drawings rather than from the enquiry, and the canopy height over seated guests is a drawing item — it is usually the last thing to be signed off and the first thing to delay a build.

Yes — NFPA 701 fire-retardant foliage is available as an option on every tree, and EN 13501 B-s1,d0 is available for EU projects, with batch test reports archived against your order.

Yes. Crown scale and trunk detailing are drawn to the sight lines of your specific atrium, so the tree looks right at 3 m and at 10 m alike.

Yes — 3–6 m with a 2–4 m canopy on a sculpted multi-stem trunk, with canopy height set to clear seated guests and wipe-clean matte PE foliage for daily service. No structural work is required for installation, and the finish is specified per project rather than off the shelf.

Configure This Tree for Your Hotel Atriums & Lobbies

Height, trunk finish, foliage density, planter and base plate — tell us the venue and we'll send CAD options within 12 business hours.

WhatsApp an Engineer All Solutions